Similar to the spectral case there is the tool lc_pick (see [1] for details) to combine the lightcurves from the single Science Windows.
lc_pick group="og_jmx2.fits" source="Crab"\ lc="crab_lc.fits"The resulting file contains two lightcurves, one for each energy band. One of the obtained lightcurves is shown in Figure .
It is also possible to sum up lightcurves from different observation groups. The method to do this is the same as in the spectral case, and is explained in section .
The vignetting by the collimator and mask support structure of JEM-X has a more complex structure than originally thought. Therefore, source fluxes can vary significantly, of the order of 10%, from one Science Window to the next. At off-axis angles of 5 degrees this can even reach 30% in bad cases. The modeling of vignetting at the IMA and SPE steps is at the moment much better than this.